Link Pil1-3Ps2 Client Port To Transponder/Muxponder Edge Port - Fujitsu 1FINITY L100 User Manual

Table of Contents

Advertisement

263
ROADM Turn-Up and Operations

Link PIL1-3PS2 Client Port to Transponder/Muxponder Edge Port

7.8

Link PIL1-3PS2 Client Port to Transponder/Muxponder Edge Port

Step 1
Link a PIL1-3PS2 client port to a remote transponder/muxponder edge port.
Commands:
% set eqpt shelf 3 slot 1 subslot 0 port C1 remoteDestPeerPort-id "FWCDS-01 1-1-2"
% set eqpt shelf 3 slot 1 subslot 0 port C1 remoteSrcPeerPort-id "FWCDS-01 1-1-2"
Note: The preceding example shows a link to a FLASHWAVE CDS port.
% set eqpt shelf 3 slot 1 subslot 0 port C3 remoteDestPeerPort-id "T200-NE1 1/1/0/
E1"
% set eqpt shelf 3 slot 1 subslot 0 port C3 remoteSrcPeerPort-id "T200-NE1
1/1/0/E1"
Note: The preceding example shows a link to a 1FINITY T200 port.
✓ 
This task is complete.
·