GRAPHTEC GL2000 User Manual page 104

Midi logger hv
Hide thumbs Also See for GL2000:
Table of Contents

Advertisement

Setting
(3) Scaling
Span
(4) Dec pt
(5) Upper
(6) Lower
(7) Select
(8) Unit
When EU is set to OFF, m (milli) or k (kilo), etc . of engineering unit is taken into account in the calculation .
For example, 100 mV is treated as 0 . 1 .
When EU is set to ON, the engineering unit set in the EU character string is not taken into account . The
numerical value of the EU calculation result is the calculated numerical value .
Span settings
Setting
(1) Upper
(2) Lower
Set waveform color
Setting
(1) Current Color
(2) Set Color
(3) Preset Color
(4) R (red), G (green), B
(blue)
Set the scaling factor for a calculation result.
/1000000, /1000, ×1, ×1000, ×1000000
<Example>
In the case of calculation result =
0.001
Calculation result ×1 = 0.001
Calculation result ×1000 = 1
Calculation result ×1000000 = 1000
Set the upper and lower limits of values to be converted.
* For temperature input, there is no distinction between upper and lower limits. See the
setting examples shown below for details.
Set the upper limit and lower limit of the span displayed in the Y-T waveform. This setting is
for calculation only.
When Operation is On, this span is used instead of the span that set in [AMP] - [Misc.] - [Span
setting].
Select a specific engineering unit classification. (The following are available.)
Cur, Length, Area, Volume, Velocity, Accel, Freq, Mass, Energy, Pressure, Flow , Temp,
Strain, Brightness, Concentration; Optional
Select a unit to be used after conversion.
A unit displayed in this field belongs to the classification selected in "Select".
To set a unit not displayed in this field, set arbitrary text in "Arbitrary unit." The setting
selected in this field is displayed in "Arbitrary unit". (Number of characters that can be
entered: Up to 8characters)
(1)
(2)
Set the upper limit of the span displayed in the Y-T waveform.
When EU setting is On, set the EU-converted value. (Numbers in [] are numbers before EU
conversion.)
Set the lower limit of the span displayed in the Y-T waveform.
When EU setting is On, set the EU-converted value. (Numbers in [] are numbers before EU
conversion.)
(1)
(2)
(3)
(4)
The currently set color is displayed.
The color to set from now is displayed.
Available colors to choose from.
Set to 0 to 31 for each of red, green, blue (RGB)
Additional selection of colors to choose from.
CHAPTER 3 Settings and Measurement
Description
In the case of calculation result =
1000
Calculation result ×1 = 1000
Calculation result / 1000 = 1
Calculation result / 1000000 = 0.001
Description
Description
3-63

Advertisement

Table of Contents
loading

Table of Contents