Procedure
1. Power down the server.
2. Make sure that the server Do not remove LED is off.
3. If installed, disconnect the tube set.
4. Disconnect all peripheral cables from the server.
5. Remove the server:
a. Loosen the release lever thumbscrew (callout 1).
b. Use the release lever to pull the server out of the bay (callout 2).
6. Place the server on a flat, level work surface.

Remove the node cover

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components
to cool before touching them.
CAUTION: To prevent damage to electrical components, take the appropriate anti-static precautions before beginning
any installation, removal, or replacement procedure. Improper grounding can cause electrostatic discharge.
CAUTION: Do not operate the server with the node cover removed. Operating the server in this manner results in
improper airflow and improper cooling that can lead to thermal damage.