Specifications

Environmental specifications

Specification
Temperature range
Operating
Nonoperating
Relative humidity (noncondensing)
Operating
Nonoperating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305 m (1.8°F per 1000 ft) to 3050 m (10,000 ft) is
applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper limit and rate of change might
be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended. The extended range
is 5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level. An altitude derating of 1.0°C per every 175 m
(1.8°F per every 574 ft) above 900 m (2953 ft) to a maximum of 3050 m (10,000 ft) is applicable.

Limited system operating temperature requirements

The maximum system operating temperature for most components installed in the system is 35°C (95°F). However, some
components in specific configurations are subject to temperature limitations. To ensure safe and reliable system operation,
observe the limited operating temperature for these configurations. For more information, see the HPE website:
https://www.hpe.com/support/xl225ngen10plus-thermal

Mechanical specifications

Specification
Dimensions
Height
Depth
Width
Weight, approximate values
Minimum
Maximum
1
Value
10°C to 35°C (50°F to 95°F)
–30°C to 60°C (–22°F to 140°F)
8% to 90%
28°C (82.4°F), maximum wet bulb temperature
5% to 95%
38.7°C (101.7°F), maximum wet bulb temperature
Value
41.30 mm (1.63 in)
616.63 mm (24.28 in)
176.15 mm (6.94 in)
4.61 kg (10.16 lb)
5.56 kg (12.26 lb)