Install the secondary riser

Prerequisites
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
Procedure
1. If the onboard SATA cable or a Smart Array controller cable is attached to the riser, do the following:
a. Route the cable underneath the riser cutout (callout 1).
b. To ensure that the cable is not caught underneath the riser during the installation, position the cable away from the
riser connector (callout 2).
2. Install the secondary riser:
a. Align the spools on the riser with the notches on the server tray (callout 1).
b. Carefully press the riser down on its system board connector (callout 2).
Make sure that the riser board is firmly seated.
c. Install the riser screws (callout 3).