6.5 Making the waste water connection

NOTICE

6.5.1 Determining the type of connection to the sewer system

Overflow of the device through an externally mounted siphon
Combi steamers have an integrated siphon.
An additional, external siphon without ventilation of the drain line will cause the
unit to overflow in these combi steamers.
Therefore, do not connect an external siphon without ventilation to the waste
water connection.
The wastewater connection needs a free outlet or vent.
Only exception:
- FlexFusion Gold without WaveClean
Waste water installation tasks
Waste water installation tasks on waste water systems and the unit
may only be carried out by a specialized company that is responsible
for waste water systems. The applicable regional regulations,
standards and guidelines must be observed, as well as the connection
conditions imposed by the operator of the waste water company
responsible.
Technical qualifications for waste water installation tasks
Waste water installation tasks on waste water lines and the unit may be
carried out only by a waste water specialist provided by the specialist
company contracted.
The units can be equipped with either an automatic or manual cleaning
system. The symbol on the control unit indicates which cleaning system
is installed.
Cleaning system
Automatic cleaning system
Manual cleaning system
Installation instructions
Connecting the unit
Waste water mains connection type
• Permanent connection
• Free discharge
• Free discharge