Commander 4S Module; Commander 2Tsm Analog Module - Auerswald ISDN Installation And Configuration Manual

Table of Contents

Advertisement

10
Technical Data
COMmander 4S
Module
0
Connection Options
Usage
4 S
(jumper board)
Connection Type, external
S
0
Point-to-Point connection, Euro-ISDN (DSS-1), PBX
is self powered
Connection Type, internal
S
0
nection, EURO-ISDN (DSS-1)
Connector Type
4-pole detachable screw clamp connectors, addi-
tionally western modular jacks for 2 S
Internal S
Port
0
Devices, internal
8 ISDN devices maximum, 4 line powered devices
maximum e.g. different ISDN telephones (2 tele-
phones is recommended)
Range, internal
100-200 m maximum (for bus wiring, please observe
the european standards ENV 41001 [DINV 41001]
and EN 28877)
Termination Resistors
switchable; default factory setting: on
Other Data
Installation
Slot insert in the case of the COMmander Basic
Power Supply
from COMmander Basic
Size
293 x 98 x 15 mm
Weight
app. 180 g
Safety
CE, EN 60950
ports, switchable as internal or external S
0
basic rate connection as Point-to-Multipoint or
basic rate connection as Point-to-Multipoint con-
ports
0

COMmander 2TSM analog Module

Connection Options
port
Usage
0
Connection Terminals
Connector Type
Music Input
Input Level
Input Impedance
Audio Output
Output Level
Output Impedance
Door Terminal Connection
Interface
Power Supply
Relay Contact
door bell button Input Voltage
Remote switching Relay
Contact
Alarm Input
Alarm Input Voltage
Trigger Status
Second Ringer Bell
Ringer Voltage
Min. Load Impedance
Other Data
Installation
Power Supply
Size
Weight
Safety
Technical Changes may be introduced without prior Notice
6 Relay outputs, default factory settings: 4 for the 2
possible door terminals, 4 door bell button inputs re-
configurable to alarm inputs, 1 second ringer bell
output, 1 music input, 1 audio output
removable spring clamps, Cinch jack for audio input
detachable screw clamp connectors, Cinch-connec-
tor for music input
adjustable from -18 to +10 dB (1 V
)
eff
depending on input level 25 to 50 k
1 V
maximum
eff
600
FTZ-123-D12-0
12 VDC, 100 mA each door terminal
floating, 50 V/1 A maximum
configuration dependent 0 V or
5-15 VAC/DC with door bell button (make contact)
floating, 50 V/1 A maximum
configuration dependent 0 V or
5-15 VAC/DC with alarm contact (make contact)
Contact closed for more than 0,5 sec
app. 45 V
, 50 Hz
eff
> 4 k , typ. 12 k (no door bell!)
Slot insert in the case of the COMmander Basic
from COMmander Basic
293 x 80 x 15 mm
app. 120 g
CE, EN 60950