Operation Mode „Subscriber Display" 1 and 2
In these operation modes the system display is assigned to one sub-
scriber in COMset.
100 --- --- K5 14:59
--- 350 --- }# A:3/4
530 540 550
100 --- --- K5 14:59
--- 350 --- }# A:1/2
530 540 550
Ruf an 390
In the idle mode (Example above) the system display shows the time
(14:59) and the busy status. The subscriber gets information about the
active exchange line connections (A:3/4: 3 of 4 available exchange
lines) and who can not be called at the present moment, e.g. he is cur-
rently making a call (100: Subscriber 100 can not be called, ---: Sub-
scriber is available). For this purpose you need to configure with COM-
set the 9 subscribers.
If one or more door terminals are available, a busy door terminal (T:-2:
Door 2 is busy) and a pressed door bell button (K:1---: door bell button 1
is pressed) will be displayed.
Additional informations are displayed: The currently active configuration
(K5: Configuration 5 is active). The bell (
active wake-up service configured for the subscriber. The arrow (
signalling an existing entry in the caller list that has not been called
back.
In a status line outgoing (Ruf an 390) and incoming calls or settings are
displayed that have been assigned to the subscriber. Depending of the
configuration in COMset, incoming external calls are displayed with the
caller number (Mode 1) or the called number (one of your external num-
bers; Mode 2).
Requirements for external Remote Switching and Programming
If the customer wants to program call forwarding, switch relays, activate
the alarm or monitor a room from an external telephone, you have to
make some configurations first in COMset:
One of the available external numbers must be configured as remote
switching and programming MSN/DDI. The PBX will be called via this
MSN/DDI for these purposes. This number must not be forwarded and
should not be assigned to another subscriber, otherwise you have to
configure the delay time for external remote switching and program-
ming.
Required Configurations for the time-controlled Software Update
You can perform an automatic PBX firmware update by pressing a but-
ton. During this update the PBX will make independently a telephone
connection to one of the servers at Auerswald and the current software
will be transferred while the call data and configurations will remain pre-
served.
It is also possible to activate an automatic update by the PBX in certain
time intervals (e.g. annually). The PBX tries (in a timeframe of four
hours) to connect and receive the most recent firmware from the server.
If the update was not successful in this timeframe, the PBX will try again
on the following day at the same time. The following configurations have
to be made with COMset:
K:1---
T:-2
K:1---
#
) is signalling, that there is an
By dialling a number pre-configured with COMset you will reach the
main menu of the system display. Pressing the digits displayed in the
main menu you will get into the other menus (e.g. for display of the caller
list, the call charges, wake-up times and configuration switching times).
You can go one level back by pressing the * key. This is easy to use.
Please consult the manual of the system display.
Operation Mode „Reception" 3
In this operation mode, the system display is not assigned to a certain
subscriber. Among other things the system display shows the time
(14:59) and the busy status. The receptionist gets information on the
active exchange line connections (A:1/2: 1 of 2 available exchange
lines) and who can not be called at the present moment, e.g. he is cur-
rently making a call (125: Subscriber 125 can not be called, ---: Sub-
scriber is available).
If more than 10 subscribers are indicated (in COMset up to 30 or 35
subscribers can be configured without door/switching module, multiple
display of a subscriber is possible) and toggle display is switched on,
the display changes from one page to the other in short intervals.
If one or two door terminals are available, a busy door terminal (T:1-:
Door 1 is busy) and a pressed door bell button (K:--3-: door bell button
3 is pressed) is displayed. The status of the six relays is also displayed
(R:1-3---: Relay 1 and 3 are switched on). The currently active configu-
ration (K2: Configuration 2 is active) is also displayed.
A:4/6
T:1- K:--3- R:1-3---
125 126 --- --- 129
}
) is
500 --- --- --- ---
--- 319 320 --- ---
300 --- 500 --- ---
444 --- --- 447 ---
--- --- --- --- 299
To program a call forwarding from an external telephone, the external
programming of the call forwarding must be permitted.
Please note, that strangers with knowledge of the remote switching and
programming MSN/DDI and the external password (the default factory
setting is identical for all PBX) may be able to program a call forwarding
(and may generate call charges on the bill of the PBX owner). You bet-
ter change the external password if you plan to do these settings.
Please select how often (time interval) an automatic update should be
performed.
Select the time (time frame of four hours) for the update to minimize the
effects of an automatic updated on the daily work schedule.
Activate firmware update immediately, if the update should be per-
formed without preserving ongoing calls.
Select also, if the PBX should also additionally update the connected
system telephones (COMfort 1000, 1200 and 2000) with the most
recent firmware. First only one system telephone will be updated via
external ISDN connection and the firmware will be distributed internally
from this telephone to the other system telephones.
Configuration Options
K2 12:00
49