Configure Telephone Number Presentation
Direct Output to a serial Printer
If you do not like to analyse your data on the PC, but like to send the
data directly to a printer, you can directly connect a serial printer to the
serial port
(chapter Connection via the serial port (V.24) on page
You have to configure the parameters of the serial port in the printer (no
handshake, 9600 baud, 8 bit data, 1 stop bit, no parity). The output for-
mat of the headers and footers can be customized according to the
printer and customer requirements. For printing all information a line
width of 112 characters needs to be configured in the configuration pro-
gram COMset. If a smaller line width is configured, certain columns will
not be printed. The following shortcuts/IDs are used in the printouts:
*
no number presented
Ax:yyy
Call via exchange line x and MSN yyy
TNxxx
Call of subscriber xxx
I
Type of call: Incoming.
O
Type of call: Outgoing.
B
Type of call: Business.
P
Type of call: Private.
U
Type of call: Unsuccessful.
Gxxx
Call of group xxx
Pxxxxxx
Project number xxxxxx
xxxmyys
Duration xxx minutes and yy seconds
xxxxxe
xxxxx units
CF x
Call forwarding via exchange line x
UPD
Software update
S0PR
configuration via ext. S
Alarm
alarm call
Door x
Door to external call from door terminal x
If the printer is always on and you like to see the call data of the call just
finished you have to configure the serial port to operation mode „contin-
uous call data output". If you like to remove the printer in this operation
With ISDN you have the feature to transmit your own telephone number
to the person you called or to the caller. If this one has an ISDN connec-
tion and an ISDN telephone (or a CLIP compatible analog telephone),
he will be able to see the transferred telephone number on his display
before the conversation or at the beginning of the call.
Presentation of Number to incoming Caller
For each subscriber and each group can be configured which telephone
number (MSN/DDI) will be presented in case of incoming calls. The
transmitted telephone number will enable the caller to identify whether
he is connected to the desired calling partner or whether his call was for-
warded or taken via pickup.
Presentation of private or Business Number
In COMset the telephone number to be presented in case of an out-
bound business call (for the subscribers additionally for private calls)
can be configured for each subscriber and each group.
port
0
Configure Telephone Number Presentation
mode from time to time without losing data, you will need the Start-/Stop
command for the „continuous call data output"
manual).
If the call data is printed on demand only, the operation mode of the
34).
serial port may remain „exclusive, for configuration software only". The
printing will start, if the customer enters the command for the call data
printing by telephone
Control the Call Charges with a Telephone
To control the call charges for each single subscriber, the call charges
are also registered for each subscriber in the PBX. An enquiry and dele-
tion of the charge sum can be performed from time to time
the user
manual). Deleting the charges has no effect on the call data in
the call data memory.
To control the call charges during or directly after a call, the charges are
send and displayed on ISDN telephones in the moment they occurred.
This is even the case, when the receiver is already on-hook. For analog
telephones with a charge meter display, the PBX can be configured to
translate the ISDN charging information into analog metering pulses.
If external calls are transferred to internal subscribers often, you can
configure the „Call Charge Registration with changing Subscriber", to
charge the call charges to the next subscriber from the time of transfer
on.
For the function „Call Charge Registration with changing Sub-
scriber" you need the feature „Advice of Charge during the
Call (AOCD)" on you exchange line. Otherwise all charges will
be registered to the last subscriber.
If the PBX is used e.g. in a hotel, it may be better to use a separate S
port for each room. This way you avoid the situation that a hotel guest
modifies his telephone MSN to make calls to the bill of other guests.
Please note: A subscriber configured as „ISDN PC-controller" also
accepts calls from devices without an MSN or with a different MSN pres-
entation. This enables the use of controllers that do not present an MSN
at all
(chapter Programming via PC (Interface CAPI 2.0) on page
Restriction of Number Presentation (CLIR)
If the called person should not see your telephone number, the tele-
phone number presentation of outbound and incoming calls (CLIP/
COLP) can be switched off in COMset. These settings can also be done
by each user for outbound calls on his own telephone
user
manual). He has also the possibility to restrict the number presen-
tation from call to call
You can only use this function if you applied for the ISDN serv-
ice feature „Optional restriction of the telephone number pres-
entation (CLIR)" at your provider and if it is activated.
Show the Telephone Number transmitted by the
Caller (CLIP)
The telephone number of a caller (if transmitted) is shown on the ISDN
telephones and on the optionally connected system displays SD-420
(Auerswald accessory).
If CLIP-compatible analog telephones are connected to the PBX, the
telephone number information can also be transferred to the corre-
sponding analog subscribers. In order that these telephones are able to
recognize this information without problems, you are in need of a spe-
cial ringer signal that must be switched on for these subscribers. Show
CLIP Information has to be switched on for these subscribers in COM-
set. All other subscribers better switch off this function (default factory
setting).
(page 33 in the user
(page 34 in the user
manual).
(page 12 in the user
manual).
(page 32 in
0
50).
(page 24 in the

Advertisement

Table of Contents
loading

Table of Contents