Music Functions; Use Second Ringer Bell; Use Alarm Functions - Auerswald ISDN Installation And Configuration Manual

Table of Contents

Advertisement

52
Configure the COMmander 2TSM analog Module

Music Functions

The COMmander 2TSM analog module has an input for external Music
on Hold alternatively to the internal Music on Hold stored in the PBX.
You can connect e.g. a CD player here. If the connected CD player
should not to be powered-on all the time, it can be activated by a relay
as soon as it will be needed. You have to configure the operation mode
Music on Hold and the requested Switching time for the relay in
COMset.
If you want to change the internal Music on Hold, there is an alternative
to the external Music on Hold input. It is also possible to store another
music than the existing internal Music on Hold in the PBX. This can be
done with COMtools Music on Hold (save a song as wave file
PBX) as well as via telephone (record a song with the PBX on the exter-
nal Music on Hold input)
(page 43 in the user

Use second Ringer Bell

If a subscriber of the PBX likes to hear the bell ringing also on places
where he cannot hear his telephones, you can connect a second ringer
bell to the COMmander 2TSM analog module. The assignment for dif-
ferent call types (when it has to ring) can be configured In COMset.
1. Standard Windows format for audio data
1)
in the
manual).

Use Alarm Functions

The alarm procedure can be as follows:
Alarm detection at the alarm input (contact closed longer than ½ a
second).
The configurable alarm delay time is running (0-99 seconds).
Non recurring start of the siren (for 1-99 seconds) and/or the alarm
indication light (for 1-99 minutes).
Simultaneously the first alarm call run starts (Alarm calls to the
alarm subscribers):
Calling the first alarm subscriber for 60 seconds. Internal alarm
subscribers are called with a special ringer rhythm (ISDN tele-
phones: See manual of your telephone).
After taking the receiver, you will hear an alarm announcement
stored in the COMmander Basic
again and again. The called party must acknowledge the alarm
call within 60 seconds by sending the DTMF number
in the user
manual).
If the called party does not acknowledge the alarm call, the next
alarm subscriber will be called some seconds after finishing the
first call. And so on....
If all alarm subscribers are called without receiving an acknowl-
edgement, the alarm run will be repeated after a configurable alarm
waiting period (0-99 seconds) has elapsed (you can configure 1-10
alarm runs).
The alarm will be terminated (including siren and alarm indication
light), as soon as one of the alarm subscriber acknowledges the
alarm. If the alarm input has been configured to „active once", it is
deactivated afterwards. If the alarm input has been configured to
„active repetitive", it is activated again and a new alarm can be trig-
gered.
If the alarm function of the PBX has to be used the following settings are
necessary in COMset:
For the door key input the door key determination alarm as well as
kind of contact have to be configured. With the corresponding circuity
(e.g. output of an alarm system) an alarm can be activated.
To control a siren and/or a code light, a relay has to be set the operation
mode siren or code light with the requested duration timing.
You can enter up to four internal and external telephone numbers under
alarm subscribers 1-4. It is recommended for calling external alarm
subscribers to activate emergency call has priority.
Depending on how often and how long an alarm has to be signalled,
modify the settings for alarm cycles, alarm time delay as well as alarm
waiting period.
You may activate the alarm function now. But the alarm can also be
activated or deactivated by an internal or external telephone
in the user
manual).
(page 46 in the user
manual)
0
(page 22
(page 43

Advertisement

Table of Contents
loading

Table of Contents