Figure 121. Stripping the Power Wires
Note
You must use stranded wires with the terminal lugs. You may not
use solid wires.
2. Insert the power wires into the terminals included with the power
supply and use a crimping tool to secure the wires to the terminals.
See Figure 122.
Figure 122. Attaching the Power Wires to the Straight Terminal Lugs
3. Verify that the On/Off switch on the AT-SBxPWRSYS1 DC Power
Supply is in the Off position. Refer to Figure 123 on page 191.