Maximum
The ports have a maximum operating distance of 100 meters (328 feet).
Distance
Cable
The cable requirements for the ports on the AT-SBx81GT24 and AT-
SBx81GT40 Line Cards and AT-SBx81XLEM/GT8 Expansion Module are
Requirements
listed in Table 17.
Table 17. Twisted Pair Cable for the AT-SBx81GT24 and AT-SBx81GT40
SwitchBlade x8112 Chassis Switch and AT-SBx81CFC400 Card Installation Guide
Note
Switch ports that are connected to 10 or 100 Mbps end nodes that
are not using Auto-Negotiation should not use Auto-Negotiation to
set their speed and duplex mode settings, because duplex mode
mismatches might occur. You should disable Auto-Negotiation and
set the speed and duplex mode settings manually with the
AlliedWare Plus Operating System.
Note
The ports on the AT-SBx81GT40 Line Card and AT-SBx81XLEM/
XT4 Expansion Module only support full-duplex mode.
Line Cards and AT-SBx81XLEM/GT8 Expansion Module
Cable Type
Standard TIA/EIA 568-B-
compliant Category 3 shielded
or unshielded cabling with 100
ohm impedance and a
frequency of 16 MHz.
Standard TIA/EIA 568-A-
compliant Category 5 or TIA/
EIA 568-B-compliant Enhanced
Category 5 (Cat 5e) shielded or
unshielded cabling with 100
ohm impedance and a
frequency of 100 MHz.
Standard TIA/EIA 568-B-
compliant Category 6 shielded
cabling.
Standard TIA/EIA 568-C-
compliant Category 6a shielded
cabling.
10Mbps
100Mbps
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
1000Mbps
No
Yes
Yes
Yes