Step 6: Adjust the Image Quality

Display the camera image and adjust the image quality.
Display the Image
Display the image captured by the camera. When you click the Play button, the camera image
appears in the right area.

Adjust the Gain

The gain control uses Analog Base Gain and Digital Gain.
Analog Base Gain can be set at 0dB, +6dB or +12dB.
l
The digital gain is used for the master gain setting.
l
For setting the gain,
1. Set analog gain (Select from 0dB, +6dB and +12dB).
2. Set digital gain.
The master gain (DigitalAll) can be set x1 (0dB) to x16 (+24dB) against the analog base gain.
The resolution for gain setting is x0.01/step which is 0.05dB to 0.08dB, depending on the setting
value.

Adjust the Black Level

The black level can be set in the following range.
DigitalAll: -256 ~ +255