GS2512-WXTBD
Item
Power supply voltage
Power
Under the maximum load
consumption
Main unit
Main unit (Backlight OFF)
Inrush current
Permissible instantaneous power failure time
Noise immunity
Withstand voltage
Insulation resistance
Applicable wire size
Applicable solderless terminal
Applicable tightening torque
(Terminal block terminal screw)
4 SPECIFICATIONS
48
4.3 Specifications of Power Supply Section
Specifications
24 V DC (+10%, -15%)
20 W or less
14 W
8 W
59 A or less (2 ms, ambient temperature: 25 °C, under the maximum load)
5 ms or less
Noise voltage: 500 Vp-p, noise width: 1 μs, measured by a noise simulator with noise frequency ranging
from 25 Hz to 60 Hz
350 V AC for 1 minute across power terminals and earth
500 V DC across power terminals and earth, 10 MΩ or more by an insulation resistance tester
2
2
0.75mm
to 2 mm
(AWG 14 to 18)
Solderless terminal for M3 screw RAV1.25-3, V2-S3.3, V2-N3A, FV2-N3A
0.5 N·m to 0.8 N·m