Maintenance Plan; Before Every Start-Up Of Unit; Daily; Weekly Or After Tool Breakage - Planmeca PlanMill 50 S User Manual

Table of Contents

Advertisement

11.4 Maintenance plan

11.4.1 Before every start-up of unit

11.4.2 Daily

11.4.3 Weekly or after tool breakage

User's manual
3. Pull out the coolant tank.
4. Remove the coolant tank lid.
5. Fill or empty the coolant tank. The capacity of the coolant tank is 1.8
litres.
6. Close the coolant tank lid.
7. Make sure that the feed line and the float are in the uppermost position.
8. Push the coolant tank all the way to the back of the unit.
9. Push the feed line and the float downwards.
10. Make sure that the feed line and the float are positioned in the recess
provided in the lid of the coolant tank and that the function of the float is
guaranteed.
11. Close the coolant tank access door.
Clean the workpiece holder
Clean the tool holder
Clean the tool shank on all tools
Clean the length probe
Clean the interior of the unit
Check the water separator and empty if necessary
Remove the collet chuck
Clean the collet chuck
Check the collet chuck for damage
11 Preventive maintenance