Planmeca PlanMill 40 S User Manual
Hide thumbs Also See for PlanMill 40 S:

Advertisement

Quick Links

Planmeca PlanMill
40
S
®
user's manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PlanMill 40 S and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Planmeca PlanMill 40 S

  • Page 1 Planmeca PlanMill ® user's manual...
  • Page 3: Table Of Contents

    Turning off the milling unit ...................... 6 Relocating the milling unit ....................... 6 System information and upgrades ..................8 FOR YOUR SAFETY ......................9 MANAGING PATIENTS IN PLANMECA ROMEXIS ............. 11 IMPORT FOR MILLING ..................... 11 OPERATING THE MILLING UNIT ..................12 Pending jobs ......................... 12 Inserting blocks ........................
  • Page 4 IEC 60364 - equipment is used according to the operating instructions. Planmeca pursues a policy of continual product development. Although every effort is made to produce up-to-date product documentation this publication should not be re- garded as an infallible guide to current specifications. We reserve the right to make changes without prior notice.
  • Page 5: Introduction

    This manual described how to operate the Planmeca PlanMill 40 S as part of the Planmeca Chairside CAD/ CAM solution. 1.1 Indications for use The Planmeca PlanMill 40 S is a dental milling unit used to fabricate restorations from compatible dental materials. 2 ASSOCIATED DOCUMENTATION •...
  • Page 6: Symbols On Product Labels

    Directive 2002/96/EC (WEEE) UL Laboratory Equipment Listing IN ACCORDANCE WITH UL 61010-1 30SC E253493 OFF Power IEC 60417-5008 ON Power IEC 60417-5007 On/Off Power IEC 60417-5010 Operating Instructions ISO 7000-1641 Protective Earth IEC 60417-5019 Planmeca PlanMill 40 S User’s manual...
  • Page 7: Label Locations

    The serial number is located inside the milling unit above the tank. NOTE If any of the labels are missing or illegible, please contact MILLING MACHINE Planmeca Customer Support for replacement labels. SN XXXXXX MANUFACTURED NOTE XXXXXXXXX XXXX Label examples are not shown actual size. The labels may have changed since this book was published.
  • Page 8 3 SYMBOLS ON PRODUCT LABELS 3.1.2 Attention labels Attention labels are located in numerous places on the Planmeca components. These labels direct you to specific safety entries in this user manual. Adhere to all such safety warnings at all times.
  • Page 9: Milling Unit

    Diagnostic mode Red (flashing) The milling unit has faulted. Warning screen: Re-initialize to clear the fault or enter the diagnostic state to attempt to diagnose the problem. White Lid is open. Yellow Warning message displayed. User’s manual Planmeca PlanMill 40 S...
  • Page 10: Turning Off The Milling Unit

    Ensure no milling operations are in progress. Open the front access panel and remove the fluid reservoir. Empty the fluid reservoir according to your approved material disposal protocols. Turn OFF the milling unit. Disconnect all power and data connections. Planmeca PlanMill 40 S User’s manual...
  • Page 11 If it is necessary to place the milling unit below the level of their waists, each person lifting should follow these procedures in reverse order, keeping their backs vertical and bending at the knees. • Be careful to avoid obstacles. User’s manual Planmeca PlanMill 40 S...
  • Page 12: System Information And Upgrades

    System software and hardware upgrades are initiated through Planmeca only. No software or hardware should be added or deleted to/from the Planmeca systems without prior approval of Planmeca. Doing so may result in damage to the system and will void the product warranty.
  • Page 13: For Your Safety

    Do not block any of the product’s cooling vents. Doing so may result in overheating and damage to the products and will void the product warranty. When placing components, adhere to all clearances stated in section in section 11 "TECHNICAL SPECIFICATIONS" on page 22. User’s manual Planmeca PlanMill 40 S...
  • Page 14 Ensure your products are properly maintained through periodic maintenance. If you suspect equipment malfunction or failure, discontinue using the products and contact Planmeca Technical Support immediately. Do not attempt to make any repairs on the products. Read and comply with all safety, warning, and instructional labels on the products.
  • Page 15: Managing Patients In Planmeca Romexis

    6 MANAGING PATIENTS IN PLANMECA ROMEXIS 6 MANAGING PATIENTS IN PLANMECA ROMEXIS For instructions see Planmeca Romexis (10014593) or Planmeca FIT solution User’s manual (10033946). 7 IMPORT FOR MILLING For instructions see Planmeca Romexis (10014593) or Planmeca FIT solution User’s manual (10033946).
  • Page 16: Operating The Milling Unit

    The system opens the lid and prompts you to insert the block that matches the material selected in the Design software. NOTE To return to the case list touch the Stop button. Planmeca PlanMill 40 S User’s manual...
  • Page 17: Inserting Blocks

    The round blocks are inserted with vertical orientation. Insert the Mandrel T-Handle into the cam and turn 180 degrees counter-clockwise to loosen the cam. User’s manual Planmeca PlanMill 40 S...
  • Page 18: Composite Block Defoaming Solution

    Zirlux FC2. If the zirconia is contaminated with other materials, it will turn green when sintered. Cleaning after milling is recommended because the zirconia acts as a thickening agent with the water. Planmeca PlanMill 40 S User’s manual...
  • Page 19: Starting Milling

    Milling continues as usual. 8.7 Deleting jobs Click the trash can button next to a job to delete it. Deleted jobs cannot be recovered on the milling unit, but can be resent from the design software. User’s manual Planmeca PlanMill 40 S...
  • Page 20: Automatic Tool Changer

    Change the tool when it turns red. To fill the tool changer, exchange tool shapes, or to replace broken tools see section 8.8.3 "Replacing / inserting tools" on page 18 for instructions. Planmeca PlanMill 40 S User’s manual...
  • Page 21 Select the job to restart milling. The system will prompt you to insert a new block at the beginning of the restarted milling process. To continue milling with a new tool, click Yes. To deactivate this feature, contact Customer Support. User’s manual Planmeca PlanMill 40 S...
  • Page 22 When placing a new tool in the collet, ensure it is pushed all the way in (fully seated). The system measures new tools and suggests a tool shape. Select a different tool type if necessary. Close the lid when finished. Planmeca PlanMill 40 S User’s manual...
  • Page 23: Troubleshooting/Repair

    9 TROUBLESHOOTING/REPAIR 9 TROUBLESHOOTING/REPAIR If you have questions, please contact Planmeca Customer Support. Symptom Probable cause Corrective action Power cable unplugged Verify power cable is plugged into a live AC outlet. Power supply switch turned OFF Set power supply rocker switch...
  • Page 24: Preventive Maintenance / Cleaning

    Refill the tank before starting your next job. Slowly pour one gallon of water into the chamber and watch the fill indicator. Stop when it blinks blue. Add 90 ml (3 ounces) of milling coolant. Continue with the normal milling procedure. Planmeca PlanMill 40 S User’s manual...
  • Page 25: Maintenance Before Zirlux Fc2 Milling

    To proceed with cleaning: Click Next. Select the Guided or Advanced wizard. Follow the on-screen instructions. Close the lid when finished. User’s manual Planmeca PlanMill 40 S...
  • Page 26: Technical Specifications

    11 TECHNICAL SPECIFICATIONS The components use standard electrical current and do not need to be attached to a water supply or drain. Model type Planmeca PlanMill 40 S Electrical ratings: 100-240 Vac, 1000 W, 50-60 Hz Air requirements: 3,5 - 9 bar (50 - 130 psi), 60 l/min (2 cfm)
  • Page 27: Approvals

    11 TECHNICAL SPECIFICATIONS 11.2 Approvals International CB Scheme Test Certificate (UL) Quality System Certifications ISO 13485 Registered Firm Japan GMP North America Product Safety Mark (NRTL) - UL C/US User’s manual Planmeca PlanMill 40 S...
  • Page 28: Disposal

    Planmeca for reprocessing. For more information about where you can send your waste equipment for recycling, please contact your local city office or Planmeca.
  • Page 30 Planmeca Oy | Asentajankatu 6 | 00880 Helsinki | Finland tel. +358 20 7795 500 | fax +358 20 7795 555 | sales@planmeca.com | www.planmeca.com...

Table of Contents