17 Technical specifications
Maximum speed
Weight
17.2 Connected loads
Mains voltage, frequency and power
17.3 Environmental conditions
Unit operating conditions
Storage conditions
Transportation conditions
Air supply
Air pressure
Air purity
114
Planmeca PlanMill 50 S
Voltage: 100/230 V
Nominal current: Max. 6 A
Frequency: 60/50 Hz
Nominal power: 750 W
Required air pressure: 6 to 9 bars (constantly present)
Required air flow rate: 60 l / min
Temperature range: 18 - 25 °C (64 - 77 °F)
Max. air humidity: 60%
Altitude: < 2000 m (6 562 ft) above sea level
Temperature range: 10 - 50 °C (50 - 122 °F)
Max. air humidity: 80%
Temperature range: -10 - 55 °C (14 - 131 °F)
Max. air humidity: 80%
NOTE
The individual components of the milling unit possess varying expansion
coefficients. Imprecision during processing can only be ruled out with an
ambient temperature from +18 to +25°C. If your ambient temperatures do
not lie inside this range then we recommend an air conditioning unit. Please
contact your local dealer in this regard.
The compressed air supply must comply with the following conditions:
Specification according to ISO 8573-1, Compressed Air for General Use,
Part 1: Impurities and Quality Classes.
6-9 bar
Connection: Plug-in nipple NW 7.2 mm (quick connection)
Solid contaminants class 3 – degree of filtration better than 5μm for solids
Water content class 4 – maximum pressure dew point +3 °C (37 °F)
60,000 rev/min
approx. 2.1 kg (4.6 lbs)
User's manual