Input Source Selection; Input Meter; Mute Button; System Processor Input Equalizer - EAW UMX.96 Owner's Manual

Hide thumbs Also See for UMX.96:
Table of Contents

Advertisement

EAW UMX.96 Owner's Manual
12.5.1.2

Input Source Selection

To change an input source, touch the source name window (A, B, C in the figure) of the desired System Processor
Input and select the new source from the Channel Select screen that appears. Choose from the following sources:
Aux/groups 1-24, Post Fader
Matrix 1-8, Post Fader
Left, Right, or Center/Mono, Post Fader
None
12.5.1.3

Input Meter

This meter indicates the signal level at the system processor's input.
An OL (overload) LED at the top of the meter indicates when the signal
reaches clipping.
12.5.1.4

Mute button

Touch this button to mute the input signal. When the input is muted, there is no signal at any of the proces-
sors outputs.
12.5.1.5

System Processor Input Equalizer

Touch the EQ button to access the equalizer screen. The LED below the EQ button indicates when the EQ is enabled.
The equalizer has six fully parametric bands. Bands 1, 2, and 3 can operate as low-frequency shelves, and
Bands 4, 5, and 6 can operate as high-frequency shelves (or they can be peak/dip). Each band's controls are
adjustable via Touch and Spin.
Control
Range
Band In
In/Out
Gain
±15 dB
Frequency
20 Hz-20 kHz
Q
0.1-64
Type
6 dB/oct shelf
12 dB/oct shelf
peak/dip
Description
The band numbers can appear in any order.
Default frequencies: 100, 200, 500, 1k, 2k, 10k Hz
Bandwidth: 6.67-0.02 octaves (see Section 8.4.7.1)
Bands 1-3 shelves are for low frequency
Bands 4-6 are for high frequency
12-54
Touchscreen Interface

Advertisement

Table of Contents
loading

Table of Contents