Hydraulic oil tank

WARNING
Burn hazard!
Before performing any service on the hydraulic system, you must allow it to cool. Hydraulic fluid
temperature should not exceed 40 °C (104 °F).
Failure to comply could result in death or serious injury.
Drain water and sediment from the hydraulic oil tank every 250 h
1. Release all the pressure in the hydraulic tank. Re-
fer to page 6-8.
2. Place a receptacle of a suitable capacity under the
drain plug.
3. Open the drain plug on the bottom of the tank and
drain the sediment and water accumulated at the
bottom of the tank.
4. After draining, close the drain plug.
5. Add hydraulic oil if necessary.
6 - MAINTENANCE