5. Remove the T-15 Torx screw, EMI shield from the rear of the CD drive and disconnect
the power cable. If the optional floppy drive is installed, you will need to repeat this
step. See Figure 2-49. Grasp the EMI shield and swing out away from the rear of the CD
drive or Floppy disk drive. Pull slightly outward to detach the hinged EMI shield from
the slot in the CD or Floppy drive bay.
Figure 2-49. EMI Shield
CD Drive and
Floppy Drive
Power Cables
Chapter 2
Parts Replacement Procedures
Power Supply
EMI Shield(s) and
T-15 Torx Screw(s)
59