2
Parts Replacement Procedures
This section describes how to remove and replace components and assemblies in the B2000
workstation.
Front Bezel and Left Side Panel
Figure 2-1. Front Bezel
Power
Switch
Opening the Front Bezel
Perform the following steps to open the workstation.
1. Power off the workstation and unplug the workstation.
2. Attach the static-grounding wrist strap by following the instructions on the package.
Attach the sticky end of the wrist strap to bare metal on the back panel of the
workstation.
3. Unlatch the front bezel by pressing in on the two latch buttons located on the right side
of the front bezel. See Figure 2-1.
4. Swing the panel outward on its left snap hinges until the panel releases and place the
front bezel in a safe location to avoid damage.
Latch Buttons
15