Using Logs
•
FRU Position
The FRU involved in the event and the slot position in the chassis relative to
identical FRUs installed.
•
Event Data
Up to 32 bytes of supplementary information for the event in hexadecimal format.
For detailed information on event data and problem resolution, refer to the hp
StorageWorks edge switch 2/16 service manual (A7284-96002/AA-RS2JA-TE).
Hardware Log
The hardware log displays information field replaceable units (FRUs) inserted and
removed from the switch.
Figure 4–4: Hardware Log
Each log entry includes the following:
•
Date/Time
Date and time of the insertion or removal of the FRU.
•
FRU
The name of the inserted or removed FRU.
4–6
FAN
Fan module
PWR
Power supply module
SFP
SFP transceiver.
CTP
CTP card. Note: The CTP is not a FRU.
edge switch 2/16 product manager user guide