Monitoring and Managing the Switch
— Faulty or dirty cable connection.
— Faulty host bus adapters that do not send out FLOGI within reasonable time
frame.
Segmented E_Port Messages:
Incompatible operating parameters, such as resource allocation time-out values
(R_A_TOV) or error-detect time-out values (E_D_TOV) are inconsistent. Refer
to
Configure Operating Parameters on page 3-4
Duplicate domain IDs. Refer to
more information.
Incompatible zoning configurations. Refer to sections on joining zoned fabrics in
the hp StorageWorks edge switch 2/16 service manual
(A7284-96002/AA-RS2JA-TE) and the hp StorageWorks ha-fabric manager user
guide (A6534-96024/AA-RS2CA-TE) for details.
Build fabric protocol error.
No principal switch (no switch in fabric is capable of being principal switch).
No response from an attached switch.
Inactive Messages:
Optics speed conflict. An inactive state will occur if you set the port's data speed to 2
Gb/sec for a 2 Gb/sec port module, and then replace the port module with a 1 Gb/sec
module. To activate the port in this case, replace the module with a module that
supports 2 Gb/sec data speed.

Displaying Switch Information

Double-click the switch illustration, away from a hardware component, to display the
Switch Properties dialog box as shown in the following figure.
2–12