Configuring the Switch
Click this check box to display a check mark and enable clock alert mode. If this
is enabled, the following occurs when users set the date and time through the
Configure Date and Time dialog box (Configure menu):
— If a user enables Periodic Date/Time Synchronization, an error message
displays indicating that Clock Alert Mode must be cleared to enable
automatic synchronization of the date and time.
— If a user manually sets the date and time (Periodic Date/Time Synchronization
is not enabled), a confirmation dialog box will display. The user must click
OK on that dialog box to continue manual configuration.
Host Control Prohibited
Click the check box in the Host Control Prohibited field to display a check mark
and prohibit a host management program from changing configuration and
connectivity parameters on the switch. In this case, the host program has
read-only access to configuration and connectivity parameters. Clicking the check
box when it contains a check mark removes the check mark and allows a host
program to change configuration and connectivity parameters on the switch.
Programmed offline state control
Click this check box to display a check mark and enable a host management
program to control the switch's offline and online state. When a check mark is not
displayed, a host program cannot set the switch online or offline.
Active=Saved
Click this check box to display a check mark and enable the Active=Saved
function for the IPL address configuration.
— If Active=Saved is enabled (check mark), the IPL and the active address
configuration are maintained as identical configurations. If a new
configuration is activated through the Configure Addresses - "Active" dialog
box, that configuration becomes the IPL address configuration.
— If Active=Saved is not enabled (no check mark), the IPL address
configuration and the active configuration are not maintained as identical and
may, in fact, be different configurations. If the feature is not enabled, you can
modify the IPL configuration through the Configure Addresses - "Active"
dialog box. If the feature is enabled, the IPL file is locked to modification
through the Configure Addresses - "Active" dialog box.
Code Page
3–22
edge switch 2/16 product manager user guide