Welding Data Memory; Fault Codes - ESAB Caddy TA33 Instruction Manual

Hide thumbs Also See for Caddy TA33:
Table of Contents

Advertisement

GB
4

WELDING DATA MEMORY

Two different welding data settings can be stored in the control panel memory.
Press button
memory. The welding data is stored when the green indicator lamp starts to flash.
To switch between the different welding data memories press button
.
The welding data memory has a back--up battery so that the settings remain even if
the machine has been switched off.
5

FAULT CODES

The fault code is used to indicate that a fault has occurred in the equipment. It is
indicated in the display by an E followed by a fault code number.
A unit number is displayed to indicate which unit has generated the fault.
Fault code numbers and unit numbers are shown alternately.
If several faults have been detected only the code for the last occurring fault is
displayed. Press any function button or turn the knob to remove the fault indication
from the display.
NOTE! If the remote control is activated, deactivate the remote control by pressing
to remove the fault indication.
bi19d2ea
or
for 5 seconds to store the welding data in the
- - 26 - -
or