2 TIG WELDING
2
TIG WELDING
2.1
Settings
Function
™2)
HF/LiftArc
2)
2/4 stroke
1)
Gas pre flow time
1)
Slope up-time
Slope down time
Gas post flow time
Current
Active panel
Changing trigger data
Remote control unit
1)
Min current
Pulse current
Pulse time
1)
Micro pulse
Background current
Background time
1)
Micro pulse
3)
Material thickness
VRD
Unit of measurement
1)
Hot Wire TIG, On/Off
Hot Wire TIG,
Arc switch-off voltage
Hot Wire TIG, Automatic start
1)
These functions are hidden Tig functions, see description in section "Hidden TIG
functions".
2)
These functions cannot be changed while welding is in progress.
3)
The setting range depend on the power source used.
0460 447 174
Setting range
HF or LiftArc
2 stroke or 4 stroke
0-5 s
0-10 s
0-10 s
0-25 s
3)
4 - max
OFF or ON
OFF or ON
OFF or ON
0-99%
3)
4 - max
0.01 - 2.5 s
0.001 - 0.250 s
3)
4 - max
0.01 - 2.5 s
0.001 - 0.250 s
30 A/mm in step of 0.1 mm
0 = inch, 1 = mm
0 = OFF, 1 = ON
2 - 30 V
1)
1)
0 = Automatic start off,
1 = Automatic start on
™
- 6 -
TA
TA
Default value
33
34
x
x
™
LiftArc
x
x
2 stroke
x
x
0.5 s
x
x
0.0 s
x
x
1.0 s
x
x
10.0 s
x
x
60 A
-
x
ON
-
x
OFF
-
x
OFF
-
x
0 %
x
x
60 A
-
x
1.0 s
-
x
20 A
-
x
1.0 s
x
-
-
-
x
-
1
x
-
OFF
x
-
x
-
OFF
© ESAB AB 2018