ALGE-Timing TDC8001 Manual page 60

Table of Contents

Advertisement

Confirm with <ENTER>
Exit main menu by pressing <ALT> and <MENU> at the same time
TdC 8001 is not connected with the start and therefore the start is not timed.
With first finish impulse display (5) shows running finish difference time and winner course.
With second finish impulse display (5) shows finish difference time and winner course
For preparing the TdC 8001 for the next race, press <ENTER>
Displays (1) and (6) show next heat number
Display (5) shows time 0.000
etc.
Penalty time:
The penalty time is used as finish difference time if a competitor drops out. When no penalty time is
required, enter 0.000 as penalty time.
When a competitor reaches the finish, the finish difference time starts. If the second competitor does not
reach the finish before the penalty time is over, the penalty time is shown on display (5) and the score-
board. The printer marks the penalty time with a "P". The penalty time is entered in the main menu (i)
(see menu 28).
Clear times:
Pressing <CLEAR> of the start keypad (12) or finish keypad (8) clears the finish impulses. The finish
impulses of the blue (c1) and red (c4) course are cleared if both have already a finish impulse.
Block times:
Every course can be blocked separately. Press <BLOCK> on start keypad (12) to print out the time of
the blue course (c4) as invalid (time of day with ?). Press <BLOCK> of finish keypad (8) to print out the
red course (c1) as invalid (time of day with ?). Pressing <ALT> and <BLOCK> at the same time the
corresponding impulse is swallowed.
Channel assignment
c0
= start channel
c1
= lap/end time
c2
= intermediate time
c3
= intermediate time
c4
= intermediate time
Default main menu:
Menu 2
delay time finish
Menu 3:
seconds mode
Menu 4:
display time 1
Menu 9:
running tenth
Menu 12:
start number automatic
Menu 13:
automatic time
Menu 16:
printer linefeed
Menu 17:
RS232 baud rate
Menu 18:
RS232 run time
Menu 19:
d-board baud rate
Menu 20:
d-board channel 2
Menu 21:
beep
Menu 25:
change race
Menu 26:
d-board test
Menu 27:
ID channel 4
Menu 28:
penalty time
Menu 53:
bib-counting
Menu 55:
LED-brightness
Menu 59:
pulse from radio
Menu 62:
extern beep
Menu 63:
RS485 user
Manual
TdC 8001
c5
= intermediate time
c6
= intermediate time
c7
= intermediate time
c8
= intermediate time
c9
= intermediate time
=
0.3 sec.
=
off
=
3 sec.
=
off
=
off
=
00:00:00.00
=
0
=
9600 baud
=
off
=
2400 baud (fix)
=
running
=
on
=
no function
=
off
=
b (blue)
=
off
=
manual
=
9
=
alle Kanäle aus
=
alle Kanäle aus
=
Wireless TN (WTN)
-60-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TDC8001 and is the answer not in the manual?