9
Spot Welding Application Using a Motor Gun
9.8
Other Functions Using a Motor Gun
Operation
1. Select [SPOT WELDING] from the main menu.
2. Select [TIP INSTALLATION].
– TIP INSTALLATION window appears.
3. Select the gun number by pressing the [PAGE] key
4. Set [MEASURE MODE].
– Move the cursor to ON or OFF. The ON/OFF mode alternate each
time pressing the select button.
• MEASURE MODE ON: The function is set for tip mounting error
detection (TWC-AE or TWC-BE).
• MEASURE MODE OFF: The function is set for wear detection
(TWC-A or TWC-B).
– Tip mounting error detection (TWC-AE or TWC-BE) functions when
executing wear detection (TWC-A or TWC-B) at ON status.
Accordingly, the difference from reference position which is
indicated on the welding diagnosis window is calculated as a tip
mounting error.
The wear is 0 cleared at this time.