Case 580SR Service Manual page 1023

Hide thumbs Also See for 580SR:
Table of Contents

Advertisement

www.maskinisten.net
HYDRAULIC HAMMER CONTROL PEDAL
At start-up, the pedal must have 12 V for the opera-
tion of the hammer.
When the switch is operated, there must be 12 V at
pin 2.
Pin No.
1
SECTION 55 - ELECTRICAL SYSTEM
Solenoid
Resistance
7.5 Ω
12 V
Copyright ©
2: R-V
1: R-V:1
1: R-V:1
2: N:1
195