ATTACHMENT SWITCH (1)
At start-up, the switch must have 12 V.
When the switch is operated, there must be 12 V at
pin 5.
REVERSING BUZZER
Activated by 12 V at key start when reverse gear is
selected.
With reverse travel selected, there must be 12 V at
pin connector.
Resistance of the buzzer 162 Ω.