Setting The Ip Address - Cabletron Systems 2208 User Manual

Cabletron systems user guide 2h22-08r smartswitch 2208
Hide thumbs Also See for 2208:
Table of Contents

Advertisement

Application (Modifiable)
Displays the application set for the COM port. This field allows you to set
the application that the COM port supports, which includes:
Local Management (LM) via a terminal or modem connection
Uninterruptible Power Supply (UPS)
The UPS setting allows you to set the COM port to monitor an American
Power Conversion Uninterruptible Power Supply (UPS). For UPS, the
baud rate is automatically set to 2400.
The baud rate setting for LM is automatically sensed.
For details about configuring the COM port for various applications, refer
to
Section
5.7.10.
Clear NVRAM (Toggle)
This allows you to reset NVRAM to the factory default settings. All
user-entered parameters, such as IP address and Community Names are
then replaced with 2H22-08R factory default configuration settings. For
details, refer to
5.7.1

Setting the IP Address

To set the IP address, perform the following steps:
1.
Use the arrow keys to highlight the IP Address field.
2.
Enter the IP address in this field using Decimal Dotted Notation
(DDN) format.
For example: 134.141.79.120
3.
Press ENTER. If the IP address is a valid format, the cursor returns to
the beginning of the IP address field. If the entry is not valid, the Event
Message Line displays "INVALID IP ADDRESS OR FORMAT
ENTERED". Local Management does not alter the current value and
refreshes the IP address field with the previous value.
4.
Use the arrow keys to highlight the SAVE command, then press
ENTER. The warning screen shown in
2H22-08R SmartSwitch 2208 User's Guide
Section
5.7.11.
General Configuration Screen
Figure 5-10
displays.
Page 5-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

2h22-08rSmartswitch 2208 2h22-08r

Table of Contents

Save PDF