Appendix A: Specifications
A.4
ENVIRONMENTAL REQUIREMENTS
Operating Temperature:
Storage Temperature:
Operating Relative Humidity:
A.5
INPUT/OUTPUT PORTS
Ports 1 through 6
Slots for optional Fast Ethernet
Interface Modules
(ports 7 and 8)
A.6
COM PORT PINOUT ASSIGNMENTS
The COM port is a serial communications port that supports Local
Management or connection to a UPS.
Table A-1
shows the COM port pin assignments.
Pin
Signal Name
1
Transmit Data (XMT)
2
Data Carrier Detect (DCD)
3
Data Set Ready (DSR)
4
Receive Data (RCV)
5
Signal Ground (GND)
6
Data Terminal Ready (DTR)
7
Request to Send (RTS)
8
Clear to Send (CTS)
Page A-2
5°C to 40°C (41°F to 104°F)
-30°C to 73°C (-22°F to 164°F)
5% to 90% (non-condensing)
Fast Ethernet 10/100 Mbps
(100BASE-TX compliant) with RJ45
type connectors.
Slots accept three types of optional Fast
Ethernet Interface Modules:
FE100-TX, FE100-FX, and FE100-F3.
Table A-1 COM Port Pin Assignments
2H22-08R SmartSwitch 2208 User's Guide
Input/Output
Output
Output
Input
Input
NA
Output
Input
NA