Setting Occupied Point - Topcon ES-62 Instruction Manual

Table of Contents

Advertisement

8.1.3 Setting Occupied Point

Occupied point can be set by two setting methods as follow.
1) Setting from the coordinate data stored in the internal memory.
2) Direct key input of coordinate data.
 Example setting: Setting the occupied point from the internal coordinate data file
Operating procedure
1
Press the {F1} (OCC.PT INPUT) key from the
Layout menu 1/2.
2
Press the {F1} (INPUT) key and enter PT#. *1)
Press the {F4} (ENT) key.
3
Enter INS.HT in the same way.
The display returns to layout menu 1/2.
*1)
Refer to Section 2.4 "How to Enter Alphanumeric Characters".
Operation
{F1}
OCC.PT
INPUT LIST NEZ ENTER
{F1}
OCC.PT
Enter PT#
{F4}
[ALP][SPC][CLR][ENT]
Enter
INSTRUMENT HEIGHT
INS.HT
INPUT
INS.HT=
{F4}
LAYOUT
8-5
8 LAYOUT
Display
PT#:
PT#=PT-01
0.000 m
--- --- [CLR] [ENT]
F1:OCC.PT INPUT
F2:BACKSIGHT
F3:LAYOUT
1/2
P

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es-65

Table of Contents