Topcon ES-62 Instruction Manual page 170

Table of Contents

Advertisement

 To show the constant list of systematic error of
instrument
1
Press the {F3} key from Adjustment Mode menu
1/2.
2
Press the {F2} key.
Correction values are displayed.
3
Press the {F1} key.
The display returns to previous menu.
*1) It is able to get the average value from 1 to 10 measurements. To get the average, repeat the
procedures in steps
*2) The compensation values of 1) Error of vertical axis (X,Y tilt sensor offset), 2) Collimation error, and 3)
Error of vertical angle 0datum will be set and memorized internally.
5
6
10
11
,
or
,
. The measured times is counted in the second line of display.
18 CHECKS AND ADJUSTMENTS
ADJUSTMENT MODE
{F3}
V0 AXIS
{F2}
VCo:
HCo: -0°00'20"
HAx: -0°00'20"
EXIT
{F1}
18-4
F1:V ANGLE 0 POINT
F2:V0 AXIS
F1:MEASUREMENT
F2:CONSTANT LIST
1°57'12"
P