Topcon ES-62 Instruction Manual page 207

Table of Contents

Advertisement

FULL
When making a file, 30 files already exist.
FILES
Initializing can not be done successful.
FAILED
INITIALIZE
LIMIT
Limit of input data exceeded.
OVER
MEMORY
Any abnormality occurs with internal memory. Initialize the internal memory.
ERROR
MEMORY
Shortage of capacity of the internal memory.
POOR
NO DATA
The data is not found in the search mode
NO FILE
There is no file in internal memory.
FILE NOT
When using a file, no file is selected.
SELECTED
When in point to line measurement, the
P1-P2
distance
horizontal distance between first point and
too short
second point is within 1m.
Known points and occupied point are on the
CIRCULAR
ERROR
same circle at the resection mode.
Same new point name is already memorized
PT# EXIST
in the memory.
When you enter incorrect name or PT# does
PT# DOES
NOT EXIST
not exist in the internal memory.
When setting a new point, calculation is
RANGE
ERROR
impossible from the measured data.
Read-only file on the USB flash drive cannot be
READ ONLY
changed and file contents cannot be deleted or
FILE
edited.
ES is outside useable temperature range and
accurate measurement cannot be performed.
Temp
RangeOUT
Tilt Over
Instrument tilts over more than 3 minutes.
An error has occurred in loading or saving
data to USB flash drive.
USB ERROR
V ANGLE
Abnormality in angle measuring system.
ERROR
H ANGLE
ERROR
VH ANGLE
ERROR
If necessary, send or delete files.
Confirm initializing data and try to initialize
again.
Input again.
Download data from internal memory to PC.
Confirm the data and search again.
If necessary, make files.
Confirm the file and select a file.
The horizontal distance between first point
and second point must be more than 1m.
Take the different point.
Confirm the new point name and input again.
Enter the correct name or enter point in the
internal memory.
Measure again.
Remove the read -only attribute of the file on
your PC etc.
Repeat measurement within the appropriate
temperature range. If the ES is used under
direct sunlight, use an umbrella to protect it
against the heat of the sun.
Level the instrument properly.
Check if the USB flash drive is formatted to
FAT32.
Insert the USB flash drive correctly.
If the error still occurs, use another USB flash
drive.
If this error code continues to display, repair
is required.