Topcon ES-62 Instruction Manual page 11

Table of Contents

Advertisement

Caution
• Perform checks at start of work and periodic checks and adjustments with the laser beam emitted under
normal conditions.
• When the instrument is not being used, turn off the power.
• When disposing of the instrument, destroy the battery connector so that the laser beam cannot be emitted.
• Operate the instrument with due caution to avoid injuries that may be caused by the laser beam
unintentionally striking a person in the eye. Avoid setting the instrument at heights at which the path of the
laser beam may strike pedestrians or drivers at head height.
• Never point the laser beam at mirrors, windows or surfaces that are highly reflective. The reflected laser
beam could cause serious injury.
• After using the Laser-pointer function, be sure to turn OFF the emission of the laser beam.
• Only those who have been received training as per the following items shall use this product.
• Read the Operator's manual for usage procedures for this product.
• Hazardous protection procedures (read this chapter).
• Requisite protective gear (read this chapter).
• Accident reporting procedures (stipulate procedures beforehand for transporting the injured and
contacting physicians in case there are laser induced injuries).
• Persons working within the range of the laser beam are advised to wear eye protection which corresponds to
the laser wavelength of the instrument being used.
• Areas in which the laser is used should be posted with a standard laser warning sign.
Symbol mark while the laser is emitting
The following symbol mark will appear at the right side
of the second line.
TILT SENSOR:[XY-ON]
X:-0°00'25"
Y: 0°00'20"
X-ON XY-ON OFF ---
x
Symbol mark

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es-65

Table of Contents