Preparation; Selecting A File For Data Collection - Topcon ES-62 Instruction Manual

Table of Contents

Advertisement

7.1 Preparation

7.1.1 Selecting a File for Data Collection

A file used by data collection mode must be selected at first.
Select a file before beginning data collection mode because selection screen of a file is displayed. And
a selection from data collection menu is possible in the mode.
Operating procedure
1
Press {F2} (DATA COLLECT) key from menu 1/3.
2
Press {F2} (LIST) key to display the list of file. *1)
3
Scroll file list by pressing {
select a file to use. *2),3)
4
Press {F4} (ENTER) key.
The file will be set and data collect 1/2 menu will
be shown.
*1) If you want to make a new file or input file name directly, press {F1} (INPUT) key and enter a file name.
*2) When a file has been selected already, '*' mark is indicated on left of current file name.
*3) Data in a file shown with arrow can be searched by pressing {F2} (SRCH) key.
It is possible to select a file from DATA COLLECT 2/2 menu in the
same way.
} or {
} key and
7-3
Operation
MENU
F1:TOP FIELD
F2:DATA COLLECT
F3:LAYOUT
{F2}
SELECT A FILE
FN:_________
INPUT LIST ––– ENTER
{F2}
AMIDATA
→*HILDATA
TOPDATA
–––
TOPDATA
{
} or {
}
→RAPDATA
SATDATA
–––
{F4}
DATA COLLECT
F1:OCC.PT# INPUT
F2:BACKSIGHT
F3:FS/SS
DATA COLLECT
F1:SELECT A FILE
F2:PCODE INPUT
F3:CONFIG.
7 DATA COLLECTION
Display
1/3
P
/M0123
/M0345
/M0789
SRCH ––– ENTER
/M0789
/M0564
/M0456
SRCH ––– ENTER
1/2
P
2/2
P

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es-65

Table of Contents