SELECTING MODE

17.1 Items of the Selecting Mode

The following modes are available.
Menu
Items
1:
TEMP. &
UNIT SET
PRES.
ANGLE
DISTANCE
FEET
2:
POWER ON
MODE SET
MODE
FINE/CRS/
TRK
HD&VD/SD
V ANGLE
Z0/H0
N-TIMES /
REPEAT
TIMES OF
MEAS.
NEZ / ENZ
HA MEMORY
ESC KEY
MODE
COORD.
CHECK
FINE
READING
Selecting item
°C / °F
hPa / mmHg /inHg
DEG(360°) /
GON(400G) /
MIL(6400M)
m / ft / ft + in
US SURVEY /
INTERNATIONAL
ANGLE MEAS./
DISTANCE MEAS.
FINE / COARSE /
TRACK
HD&VD /SD
ZENITH 0 /
HORIZONTAL 0
N-TIMES /REPEAT
0~99
NEZ / ENZ
ON / OFF
DATA COLLECT /
LAYOUT / REC /OFF
ON / OFF
0.2mm/1mm
17-1
Display
Select the unit of temperature for atmospheric
correction. Select the unit of air pressure for
atmospheric correction.
Choose degree, gon or mil unit for measuring
angle.
Choose measuring unit for distance meter, feet or
feet and inch
Select the meter / feet conversion factor.
US SURVEY feet
1m = 3.280833333333333 ft.
INTERNATIONAL feet
1m = 3.280839895013123 ft.
Select to set the measurement mode for angle or
distance when the power is turned on.
Select Fine /Coarse / Tracking mode in distance
measurement mode, when the power is turned
on.
Specify which is displayed first, horizontal and
vertical distance or slope distance, when the
power is turned on.
Choose the vertical angle reading from zenith or
from level.
Select the measurement mode for distance when
the power is turned on.
Set N (number of times) for times of distance
measurement. When setting number of times as
1or 0, it is single measurement.
Select a coordinate displaying order either NEZ
or ENZ.
Horizontal angle set can be retained after the
power is turned off.
You can select a function of the {ESC} key.
DATA COLLECT / LAYOUT: It is possible to enter
data input mode (in DATA COLLECT) or Layout
Menu from normal measuring mode directly.
REC: While executing normal or offset
measuring, the measuring data can be output.
OFF: Returns to normal function.
Select coordinate displaying ON or OFF when
setting a point.
Select 1mm or 0.2mm for the minimum reading
unit in the distance mode (FINE mode).
* This mode is for switching output format unit
when using communication commands.
Regardless of this setting, minimum reading
unit of slope distance is always set to "1 mm"
and calculated.
17 SELECTING MODE