Topcon ES-62 Instruction Manual page 55

Table of Contents

Advertisement

6
Collimate the center of the column (P1) and press
the {F1} (MEAS) key.
N-time measuring will start.
After the measurement, angle measuring display
of the left side (P2) will be shown.
7
Collimate the left side of the column (P2) and
press the {F4} (SET) key.
After the measurement, angle measuring display
of the right side (P3) will be shown.
8
Collimate the right side of the column (P3) and
press the {F4} (SET) key.
The distance between the instrument and center
of the column (P0) will be calculated.
9
To show the relative elevation (VD), press the
{
} key.
Each time pressing the {
distance, relative elevation and slope distance are
shown in sequence.
 To show coordinate of point P0, press the {
key.
10
To escape the measuring, press the {ESC} key.
The display returns to the previous mode.
} key, horizontal
}
4-14
4 DISTANCE MEASUREMENT
Collimate
COLUMN OFFSET
P1
Center
{F1}
HD* [n]
>Measuring...
Collimate
COLUMN OFFSET
P2
Left
{F4}
HR:
---
Collimate
COLUMN OFFSET
P3
Right
{F4}
HR:
---
COLUMN OFFSET
HR:
HD:
NEXT ---
COLUMN OFFSET
{
}
HR:
VD:
NEXT ---
N
P
<< m
N
P
120°30'40"
---
---
SET
N
P
180°30'40"
---
---
SET
N
150°30'40"
P
43.321 m
---
---
N
150°30'40"
P
2.321 m
---
---

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es-65

Table of Contents