3.5 Repetition Angle Measurement
•
Repetition angle measurement can be done by horizontal angle right measurement mode.
Make sure the mode is Horizontal Angle Right measurement.
Operating procedure
1
Press the {F4} (
) key to get the function on page
↓
2.
2
Press the {F2} (REP)key.
3
Press the {F3} (YES) key.
4
Collimate the target A and press the {F1} (0SET)
key.
5
Press the {F3} (YES) key.
6
Collimate the target B using the horizontal clamp
and tangent screw.
Press the {F4} (HOLD) key.
7
Recollimate target A using the horizontal clamp
and tangent screw, and press the {F3} (REL)key.
8
Recollimate target B using the horizontal clamp
and tangent screw, and press the {F4} (HOLD)
key.
9
Repeat 7 to 8 to measure the desired number of
repetitions.
Operation
{F4}
0SET HOLD HSET
TILT
{F2}
REPETITION ANGLE
---
{F3}
REP-ANGLE
0SET
Collimate A
REPETITION ANGLE
{F1}
INITIALIZE
---
{F3}
REP-ANGLE
0SET
Collimate B
REP-ANGLE
{F4}
0SET
Collimate A
REP-ANGLE
{F3}
0SET
Collimate B
REP-ANGLE
{F4}
0SET
REP-ANGLE
0SET
3-4
3 ANGLE MEASUREMENT
Display
V :
90°10'20"
HR:
170°30'20"
REP
V%
>OK?
---
[YES][NO]
COUNT[ 0]
Ht:
0°00'00"
Hm:
V/H
REL HOLD
>OK?
---
[YES][NO]
COUNT[ 0]
Ht:
0°00'00"
Hm:
V/H
REL HOLD
COUNT[ 1]
Ht:
45°10'00"
Hm:
45°10'00"
V/H
REL HOLD
COUNT[ 1]
Ht:
45°10'00"
Hm:
45°10'00"
V/H
REL HOLD
COUNT[ 2]
Ht:
90°20'00"
Hm:
45°10'00"
V/H
REL HOLD
COUNT[ 4]
Ht:
180°40'00"
Hm:
45°10'00"
V/H
REL HOLD
[Example] 4 measurement
↓
P1
↓