Dürkopp Adler 755 B Operating Instructions Manual page 343

Table of Contents

Advertisement

Troubleshooting
Error code
Symbol
5214
5215
5216
Error code 6000-6999: Error messages control
6000
6301
6351
6353
6354
6360
6361
6400
6401
6408
Operating Instructions 755 B, 756 B/F - 00.0 - 02/2021
Meaning
Reference time out stepper motor
guiding plate adjustment right
Reference time out stepper motor
folder height stop
Reference time out stepper motor
turning stop
Internal error
Data loaded from the machine ID Check machine configuration
Control defective (I2C)
Internal EEprom communication
error
Machine ID communication error Switch off the control, check the con-
Data of machine ID not valid for
this machine
No machine ID connected
Internal error
Default data loaded
No changes of machine configu-
ration.
Remedial action
• Fix blockage/sluggishness
• Replace stepper motor
• Check reference switch
• Fix blockage/sluggishness
• Replace stepper motor
• Check reference switch
• Fix blockage/sluggishness
• Replace stepper motor
• Check reference switch
• Switch off and on the machine
again
• Perform software update
 p. 285
• Inform Dürkopp Adler Customer
Service
Replace control
Switch off the control, wait until the
LED has gone out, and then switch
on the machine again
nection to the machine ID
Connect correct machine ID
Connect machine ID
• Switch off and on the machine
again
• Perform software update
 p. 285
• Inform Dürkopp Adler Customer
Service
Check machine configuration
Use USB data from this machine
341

Advertisement

Table of Contents
loading

This manual is also suitable for:

756 b756 f

Table of Contents