Dürkopp Adler 755 B Operating Instructions Manual page 341

Table of Contents

Advertisement

Troubleshooting
Error code
Symbol
3220
3500
3501
3502
3503-3507,
3520-3530
3540,
3545
3721, 3722
Error code 4000-4999: Error messages USB
4200
4301
4304
4681
Icon BFT not
available yet
Operating Instructions 755 B, 756 B/F - 00.0 - 02/2021
Meaning
• Empty bobbin
• Error Command Interpreter
• Motor synchronization Internal
error
The X and Y position are out of
min/max range
The X and Y position are within
forbidden area
• Error Command Interpreter
• Motor synchronization Internal
error
• Error Command Interpreter
• Motor synchronization Internal
error
• Error Command Interpreter
• Motor synchronization Internal
error
Machine configuration adopted
from the USB file
No USB key at the control unit
Wrong USB key
No communication with DAC
Remedial action
Change bobbin  p. 26
• Switch off and on the machine
again
• Perform software update
 p. 285
• Feedback to Dürkopp Adler
Service
Change the contour program
Change the contour program
• Switch off and on the machine
again
• Perform software update
 p. 285
• Feedback to Dürkopp Adler
Service
• Switch off and on the machine
again
• Perform software update
 p. 285
• Feedback to Dürkopp Adler
Service
• Switch off and on the machine
again
• Perform software update
 p. 285
• Feedback to Dürkopp Adler
Service
Check machine configuration
Insert USB key
Replace USB key
Check cable connection, Check
OP7000 cable at X170b DAC,
Check DAC flashing code
339

Advertisement

Table of Contents
loading

This manual is also suitable for:

756 b756 f

Table of Contents