Dürkopp Adler 755 B Operating Instructions Manual page 299

Table of Contents

Advertisement

Maintenance
For topping off the oil reservoir, use only lubricating oil DA 10 or oil of
equivalent quality with the following specifications:
• Viscosity at 40 °C: 10 mm²/s
• Flash point: 150 °C
You can order the lubricating oil from our sales offices using the following
part numbers:
Container
250 ml
1 l
2 l
5 l
Fig. 247: Lubricating
(1) - Oil reservoir
(2) - MIN marking
Proper setting
The oil level must not raise above the MAX marking (3) or drop below
the MIN marking (2).
To top off the oil:
1. Refill oil through the hole (4) in the inspection glass until the oil level
Operating Instructions 755 B, 756 B/F - 00.0 - 02/2021
CAUTION
Risk of environmental damage from old oil!
Incorrect handling of old oil can result in severe
environmental damage.
ALWAYS observe the legally prescribed
regulations for handling and disposal of mineral oil.
Take care to ensure that oil is NEVER spilled.
reaches the MAX marking (3).
Part no.
9047 000011
9047 000012
9047 000013
9047 000014
(3) - MAX marking
(4) - Hole
297