Function; Alarm keeps turning on until potential causes of a problem are eliminated.
Type; Oxygen concentration alarm,
alarm, EMF stabilization time-up alarm, Cold junction temperature alarm, Thermocouple voltage alarm,
Input current alarm, Battery low alarm, Input-pressure alarm, Cell resistance alarm
NAMUR NE 107 Alarm Display Function: Displays 4 warnings of NAMUR NE 107 standard;
F: Failure (Fault equivalent, Power supply to the heater shuts down.)
C: Function Check
S: Out of Specification
M: Maintenance Required
Data Logging Function: Stores following data to SD card or visualizes on the instrument display. SD
cards which are recommended or equivalent must be supplied by customer,
Event display; Log of Alarms, Calibration Trend, Power-on history are displayed on the main unit.
Graph Display; Displays trends of test result of resistivity from a cell resistance tester
SD card output; Measurement log (date/time, oxygen concentration, cell e.m.f, test result from a
cell resistance tester, cell condition, NE107 status, etc.) Maintenance report (setup value,
calibration value etc.) can be saved to SD cards in CSV format. The stored data can be
copied to other converter by outputting user-setting parameters to SD cards.
Sensor Self-diagnosis Function:
Calibration mode diagnose; Span/Zero compensation rate, cell response time, cell condition
Cell resistance test ; result from a cell resistance test without feeding calibration gas
• Measurement mode; auto cell resistance test, semi-auto cell resistance test,
• Cell resistance test setting; stabilization time (min. sec.) starting time (year/month/date/
hour/minute) measurement interval (day/time)
Display and setting content:
Measuring Related Items: Oxygen concentration (vol% O
Display Items: Cell temperature (°C), thermocouple reference junction temperature (°C), maximum/minimum/average
oxygen concentration (vol% O
grades), heater on-time rate (%), calibration record (twenty times), time (year/month/day, hour/minute)
Calibration Setting Items: Span gas concentration
(vol% O
), zero gas concentration (vol%
2
O
), calibration mode (automatic, semi-automatic, manual), calibration type
2
and method (zero-span calibration, zero
calibration only, span calibration only),
stabilization time (min. sec), calibration
time (min. sec), calibration interval (day/
hour), starting time (year/month/day,
hour/minute)
Output Related Items: Analog output/output mode
selection, output conditions when
warming-up/maintenance/calibrating
(during blowback)/abnormal, oxygen concentration at 4 mA/20 mA (vol%
O
), time constant.
2
Alarm Related Items: Oxygen concentration high
alarm/ high-high alarm limit values (vol%
O
), oxygen concentration low alarm/
2
low-low alarm limit values (vol% O
oxygen concentration alarm hysteresis
(vol% O
), oxygen concentration alarm
2
detection, alarm delay (seconds)
Contact Related Items: Selection of contact input 1 and 2, selection of contact output 1 to 3 (Fault,
high-high alarm, high alarm, low alarm, low-low alarm, maintenance, calibrating, range
switching, warming-up, calibration gas pressure decrease, temperature high alarm,
temperature high alarm, pressure high alarm, pressure low alarm, test result from a cell
resistance tester, alarm of a cell resistance tester, calibration coefficient alarm, cell e.m.f.
stabilization time over blowback, flameout gas detection
Standard Specification (High Temperature Humidity Analyzer)
l
Display: LCD color display of size 320 by 240 dot with touchscreen.
Analog Output:
Zero-point calibration coefficient alarm, Span-point calibration coefficient
), output current value
2
), cell e.m.f. (mV), cell internal resistance (Ω), cell condition (in four
2
),
2
<2. Specifications>
IM 11M12G01-02EN
1sh Edition : Mar. 25, 2021-00
2-16