Model and Codes
l
Model
ZR22G
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Length
-015
-040
-070
-100
-150
-200
-250
-300
-360
-420
-480
-540
Wetted material
-S
-C
Flange
(*3)
Reference gas
Gas Thread
Connection box thread
Instruction manual
--
Options
*1
Used with the ZO21P High Temperature Probe Adapter. Select flange (-Q).
*2
When installing horizontally the probe whose insertion length is 2.5 m or more, use the Probe Protector. Be sure to
specifyZO21R-L-200-□. Specify the flange suffix code either -C or -K.
*3
The thickness of the flange depends on its dimensions.
*4
Not used in conjunction with —P (pressure compensation) for reference gas. The flange thickness does not conform to JIS
specification
*5
Inconel probe bolts and U shape pipe are used. Use this option for high temperature use (ranging from 600 to 700 °C).
*6
Specify either /CV or /SV option code.
*7
Not used with the high temperature humidity analyzer.
*8
Specify either /SCT or /PT option code.
*9
Not waterproof, avoid rain. Operating maximum temperature is 80°C. Available only in the U.S.
*10
Recommended if sample gas contains corrosive gas like chlorine.
*11
Piping for reference gas must be installed to supply reference gas constantly at a specified flow rate.
*12
"/EQ" is EAC with Pattern Approval for Russia. "/ER" is EAC for Kazakhstan and Belarus.
Suffix code
Option code
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
-A
- - - - - - - - - -
-B
- - - - - - - - - -
-C
- - - - - - - - - -
-E
- - - - - - - - - -
-F
- - - - - - - - - -
-G
- - - - - - - - - -
-K
- - - - - - - - - -
-L
- - - - - - - - - -
-M
- - - - - - - - - -
-P
- - - - - - - - - -
-Q
- - - - - - - - - -
-R
- - - - - - - - - -
-S
- - - - - - - - - -
-W
- - - - - - - - - -
-C
- - - - - - - - - -
-E
- - - - - - - - - -
-P
- - - - - - - - - -
-R
- - - - - - - - - -
-T
- - - - - - - - - -
-P
- - - - - - - - - -
-G
- - - - - - - - - -
-M
- - - - - - - - - -
-T
- - - - - - - - - -
-Q
- - - - - - - - - -
-J
- - - - - - - - - -
- - - - - - - - - -
-E
-C
- - - - - - - - - -
-A
- - - - - - - - - -
/C
Valves
/CV
/SV
Filter
/F1
/F2
Tag plates
/SCT
/PT
Standard
/EQ
/ER
<2. Specifications>
Description
Zirconia Oxygen/Humidity Analyzer, Detector
0.15 m (for high temperature use)
0.4 m
0.7 m
1.0 m
1.5 m
2.0 m
2.5 m
(*2)
3.0 m
(*2)
3.6 m
(*2)
4.2 m
(*2)
4.8 m
(*2)
5.4 m
(*2)
Stainless steel
Stainless steel with Inconel calibration gas tube
ANSI Class 150 2 RF
ANSI Class 150 3 RF
ANSI Class 150 4 RF
DIN PN10 DN50 A
DIN PN10 DN80 A
DIN PN10 DN100 A
JIS 5K 65 FF
JIS 10K 65 FF
JIS 10K 80 FF
JIS 10K 100 FF
JIS 5K 32 FF (for high temperature use) (*4)
JPI Class 150 4 RF
JPI Class 150 3 RF
Westinghouse
Natural convection
External connection (Instrument air)
Pressure compensated
Rc1/4
1/4NPT(Female)
G1/2
Pg13.5
M20 x1.5
1/2 NPT
Quick connect
(*9)
Japanese
English
Chinese
Always -A
Inconel bolt
(*5)
Check valve
(*6)
Stop valve
(*6)
Dust Filter
(*7)
Dust Guard Protector
(*7)
Stainless steel tag plate (*8)
Printed tag plate
(*8)
EAC with PA
(*12)
EAC
(*12)
IM 11M12G01-02EN
2-6
Style : S2
(*1)
(*10)
(*11)
(*11)
1sh Edition : Mar. 25, 2021-00

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zr802gZr202g

Table of Contents