6.

Components

In this Chapter, the names and functions of components are described for the major equipment of
the Zirconia Oxygen/Humidity Analyzer, Converter.
In the figure listed in this manual, the example of the oxygen analyzer is shown mainly.
In the case of the humidity analyzer, unit indication may be different. Please read it appropriately.
6.1

ZR22G Detector

6.1.1

General-purpose Detector (except for ZR22G-015)

Pipe support
Bolt
Figure 6.1
Terminal box,
Non explosion-proof JIS C0920 equivalent to IP44D.
Equivalent to NEMA 4X/IP66 (Achieved when the cable entry
is completely sealed with a cable gland in the recirculation
pressure compensated version.)
Probe
This part is inserted in the furnace.
Select length from 0.4, 0.7, 1.0,
1.5, 2.0, 2.5, 3.0, 3.6, 4.2, 4.8 or 5.4 m.
Metal O-ring
U-shaped pipe
Filter
Washer
General-purpose Detector
<6. Components>
Flange
Used to mount the detector.
Select from JIS, ANSI, JPI or DIN
standard models.
Dust filter mounting screw
Calibration gas
pipe opening
Contact
Sensor (cell)
IM 11M12G01-02EN
6-1
Probe
F6-1E.ai
1sh Edition : Mar. 25, 2021-00