Avaya CS 1000 Fundamentals page 43

Sip dect fundamentals
Hide thumbs Also See for CS 1000:
Table of Contents

Advertisement

Figure 14: Deployment Kit 2 basestation
Use the following information in conjunction with the DeTeWe User Manual that accompanies
the deployment tool.
• The two DeTeWe handsets with the kit are subscribed to the basestation and are
numbered 13 and 15. To view the assembled basestation and the DeTeWe handsets, see
Figure 13: Assembled Deployment Kit 2 and DeTeWe handsets
• The key on the handset is the Off-Hook key.
Accessing site survey mode
To access the Site Survey Mode on the DECT Handset, perform the following procedure.
.
1. Press Menu.
2. Scroll down to System.
3. Dial ***76#.
4. Scroll down to Site Survey.
5. Press OK.
6. Use the handset to detect frame errors and signal strength.
SIP DECT Fundamentals
The Frame Error value for the handset is the number of detected Sync/ACRC errors
within the last 100 receiving frames; for example, 1 second. For proper deployment,
ensure the Frame Error value does not exceed 4. An Radio Signal Strength
System deployment
on page 42.
October 2012
43