Avaya CS 1000 Fundamentals page 170

Sip dect fundamentals
Hide thumbs Also See for CS 1000:
Table of Contents

Advertisement

System maintenance
• the DAP IP Range exclusive for DAPs only is selected
• the Subnet Mask is entered
• the Default gateway is entered
• the TFTP IP address (of the DAP Controller PC) is entered
• the DHCP Server is running (Activate / Deactivate / System status button)
If you use built-in TFTP Server (IP DECT Configurator), ensure
• Run TFTP Server on this PC is selected
• 3com TFTP Server on this PC is selected
• TFTP Server is running (Activate / Deactivate / System status button)
For more information, see
If you cannot make calls to or from a DECT Handset with SIPL
configuration
Perform the following steps if you cannot make calls.
1. Ensure that the SIP Line Gateway, Call Server, and DECT system are configured
2. Ensure that the DAPs are working.
3. Verify that a dial tone sounds if a handset goes off-hook. If no dial tone sounds, the
170
SIP DECT Fundamentals
DHCP and TFTP servers
and connected to the Ethernet.
SIP DECT Handset is not registered on SIP Line Gateway. Verify that the following
SIP settings are configured properly:
• For IP DECT Configurator:
- ensure that the following values are configured:
Proxy IP address = SIP Line Gateway node IP address
Proxy IP address port = SIP Line Gateway node IP address port
For more information, see
- ensure that the following values are configured: SIP domain = root domain
(SIP Line configuration)
Realm = SIP domain (case-sensitive)
user and password are entered correctly
use_registrar = yes
redirect=no
multiple_sip_ports=yes