Mitsubishi Electric NZ2GN2S1-16D User Manual page 230

Programmable controller; cc-link ie tsn remote i/o module; cc-link ie tsn communication mode
Hide thumbs Also See for NZ2GN2S1-16D:
Table of Contents

Advertisement

I/O combined module (16-point module)
■Remote register (RWr)
Device number
Name
CC-Link IE TSN Network synchronous communication function
Not used
RWr0
Use prohibited
RWr1
Error code
RWr2
Function selection status area
RWr3
Use prohibited
RWr4
Use prohibited
RWr5 to RWr9
Use prohibited
RWrA
Output Y current value Y8 to YF
RWrB
Use prohibited
RWrC
Output Y ON information Y8 to
YF
RWrD
Use prohibited
RWrE
Output Y OFF information Y8 to
YF
RWrF
Use prohibited
RWr10, RWr11
Use prohibited
RWr12, RWr13
Use prohibited
RWr2C, RWr2D
Use prohibited
RWr2E, RWr2F
Use prohibited
RWr30 to RWr4F
Use prohibited
*1 The area is used for the system.
APPX
228
Appendix 2 Remote Register
Synchronous X/Y control
mode
Use prohibited
Error code
Function selection status area
*1
Use prohibited
Use prohibited
Use prohibited
Output Y current value Y8 to YF
Use prohibited
Output Y ON information Y8 to
YF
Use prohibited
Output Y OFF information Y8 to
YF
Use prohibited
Use prohibited
Use prohibited
Use prohibited
Use prohibited
Use prohibited
Synchronization cycle
timing control mode
Use prohibited
Error code
Function selection status area
*1
Use prohibited
Use prohibited
Use prohibited
Output Y current value Y8 to YF
Use prohibited
Output Y ON information Y8 to
YF
Use prohibited
Output Y OFF information Y8 to
YF
Use prohibited
Synchronization input timing
information X0 OFF to ON
Synchronization input timing
information X0 ON to OFF
Synchronization input timing
information X7 OFF to ON
Synchronization input timing
information X7 ON to OFF
Use prohibited
Set time synchronization
control mode
Use prohibited
Error code
Function selection status area
*1
Use prohibited
Input ON/OFF information X0 to
X7
Use prohibited
Output Y current value Y8 to YF
Use prohibited
Output Y ON information Y8 to
YF
Use prohibited
Output Y OFF information Y8 to
YF
Use prohibited
Input time information X0
Input time information X7
Use prohibited

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents