Table 7-4
Table 7-4
Zone Row
Column Header
+/- Button
Scroll Bar
60
v 1.0 — February 2020
gives descriptions of the headers and buttons on the Text View screen.
Text View Screen Button Descriptions
Button
Each row in the Text view represents a heat zone in the system. Touch a
zone row and the screen will change to the Quick Set screen with the
zone highlighted.
Each header in the Text view indicates what information is shown in each
column. Touch the header and the screen will sort the values in the
column by ascending or descending order. This is identified by a red line
at either the top of bottom of the header cell. The available parameters
are as follows:
Zone = Zone number
Name = Zone name
Setpoint = Zone setpoint
Temp = Actual temperature of zone
PWR = Power output to the heater
Leakage = Earth leakage (This column is only displayed when H
cards are installed and the value has been set in the System Setup
screen.)
Amps = Current draw of the heater (Values in this column are
suppressed for XL and HL cards)
Alarm = Alarm window (Degrees above and below the setpoint
before an alarm condition is given)
Abort = Abort window (Degrees above and below the setpoint
before an abort condition is given)
Regulation = Control mode (Auto = T/C control, Manual = Fixed
% output, Monitor = Temperature only - No power output)
Watts = Calculated wattage of each heater (Values in this column
are suppressed for XL and HL cards)
220V W = Derated heater wattage for supply voltage vs. design
voltage (Values in this column are suppressed for XL and HL cards)
VAC = Output voltage to heaters (RMS calculation for power
percentage being applied to the heater)  % Power x Input Voltage
(Values in this column are suppressed for XL and HL cards)
Resistance = Calculated ohm reading for each zone (Must run mold
diagnostics first) (Values in this column are suppressed for XL and
HL cards)
Touch this button to toggle between the split and full screen views. The
split view configures the screen to show 58 zones in two columns to
maximize the number of zones that can be seen on a page. The full view
reduces the number of zones to 29, but increases the available zone
parameters that can be seen. Refer to
Use the scroll bar to scroll between pages within a screen. If all of the
available data fits in a single page, then the scroll bar will not be shown.
Description
Figure 7-7
and
Figure
Text View Screen Overview
Altanium Matrix5
7-8.